Loxone modbus5/26/2023 ![]() The accompanying web-based configuration tool allows you to set up the gateway in an easy-to-use web interface. Diese Datei wird im Ordner C:\ProgramData\Loxone\Loxone Config 10.0\Templates\Comm\ gespeichert und kann anschlieend exportiert werden. Auf diese Weise kann man sehr einfach eine groe Liste an Sensoren und Aktoren als XML-Datei speichern. Connect to Rockwell Logix, Siemens, Mitsubishi PLC's and more.ĮASY CONFIGURATION - NO PROGRAMMING REQUIRED In Loxone Config gibt es den Menpunkt 'als Vorlage speichern' im Kontextmen fr jedes Modbus Gert. You can also connect your M-Bus devices to any other industrial network by pairing the M-Bus gateway with an Anybus X-gateway for Modbus TCP. straight into your PLC system, you can get a complete overview of your site in a SCADA system, including building parameters which otherwise have to be checked separately.ĪCCESS OTHER NETWORKS - PAIR WITH AN ANYBUS X-GATEWAY The gateway decodes M-Bus telegrams making it possible to map meter values to Modbus registers. This enables central control and supervision of measuring devices which usually use the M-Bus protocol.īy getting data on consumed electricity, water, gas etc. If you cannot see the ProgramData folder you need to enable hidden folders/files in Windows explorer.Īlways make sure the file name begins with MB_ and then when your file is named click Save. You will need to then restart Loxone Config and you will see the device listed as one of the pre-defined devices.The Anybus M-Bus to Modbus TCP gateway allows M-Bus devices to communicate on a Modbus TCP network. The file path you need to save this file in is:Ĭ:\ProgramData\Loxone\LoxoneConfig version number\ENG\Comm Choose the option ‘Save as template’.Ī Save As window will pop up and you can then replace the xxx in the file name with a name for the Modbus device. Here you need to enter the IO address, choose the command type and the data type (analogue actuators only).Īgain the information relating to the IO address and the type of command and data will be provided by the manufacturer as it is product specific.Īfter adding all the required sensors and actuators to your Modbus device you can save it is a template so you can use it again.Ĭlick on the Modbus Extension in the periphery tree window to highlight it, and then right click to bring up a little menu box. Not every change for a temperature sensor). Please note therefore that too frequent polling cycles may tax the bus, so it is advisable to set sensible intervals (i.e. The data the Modbus Extension receives is forwarded via the Loxone Link to the Miniserver. The information relating to the IO address and the type of command and data will be provided by the manufacturer as it is product specific. In the Properties window of the sensor, you need to enter the IO address (register address), select the type of command, choose the data type (for analogue sensors only) and finally enter the a polling cycle (time interval in which the sensor value is updated). Select the desired type and it is added in underneath the selected Modbus device. In the top ribbon the button called ‘Sensors and Actuators’ will now show both analogue and digital sensors and actuators. To create a sensor or actuator, select the Modbus device in the peripheral tree. Single-phase energy meter, 230VAC 50Hz Direct measurement up to 32A Display of active power, voltage and current Modbus RTU interface to query the data. ![]() In this menu select ‘Modbus device’, or you can choose from a list of pre-defined devices. Modbus is chiefly used in industrial control applications. ![]() You can control up to 32 Modbus devices off one Modbus extension but all devices must have the same baud rate, stop bits, and parity settings.Ĭlick again on the Modbus Extension in the periphery tree window and you will see in the top ribbon a button called ‘Sensors and Actuators’. In a Loxone system the Modbus Extension is the master device and it can be connected with up to 32 slave devices on a 2-wire bus (exactly how RS-485 is wired with a twisted pair connecting A and B on each device). These settings are product specific so please find the details from the manufacturer’s data sheet for the Modbus device you are using. ![]() Here you must set the baud rate, stop bits and parity. ![]() If you click on the Modbus Extension in the periphery tree window you will see the Properties of the extension displayed in the properties window to the far left of the screen. A wide variety of transmitters, frequency converters, actuators, room controllers etc are already equipped with a Modbus interface. In a Loxone system the Modbus Extension is the master device and it can be connected with up to 32 slave devices on a 2-wire bus (exactly how RS-485 is wired with a twisted pair connecting A and B on each device). Modbus uses the master-slave arrangement where one device initiates all the communication activity. Modbus is a serial communications protocol that is based on the RS-485 standard. ![]()
0 Comments
Leave a Reply. |